Underfloor Heating Control Options
[tabby title=”Standard System”]
Our starter system has all that is needed to get your system running smoothly and efficiently. With nickel plated one piece brass manifolds, PERT pipe with appropriate fixings, and a set of digital stats and controls you have all the kit needed to install one of our highly efficient underfloor heating systems. We also throw in an installation manual, a set of CAD drawings and expert back up to complete the deal.
[tabby title=”Wireless System”]
Our wireless system, like the standard system, has all that is needed to get your system running smoothly and efficiently – nickel plated one piece brass manifolds, PERT pipe with appropriate fixings. The digital stats and controls are wireless, easing the installation time for the electrician. As before an installation manual, a set of CAD drawings and expert back up are included.
[tabby title=”Solo Pack”]
The single circuit mixing unit is a distribution unit ensuring reliable flow temperature control, flexible installation and easy start-up. It is comes complete with pre-wired variable speed booster pump and it is secured to anti-vibration brackets. 2 x ø15 copper pipe screw fittings for boiler inlet and return connections are also included in the package.
The Key is as follows
- Thermostatic blender
- Boiler hot water inlet (ø15 copper pipe screw fitting) + shut-off valve
- Return cold water inlet + shut-off valve
- Return to boiler (ø15 copper pipe screw fitting)
- Flow to heating system
- Heating water normally-open thermostat
- Electrical terminal block
- Booster pump (where provided)
- Mounting bracket
Attach the manifold to the wall. The floorheating pipes are fitted to outlet 5 (the flow) and outlet 3 (the return). If the pack contains two splitters, fit these to the flow and return first. The pipes are installed as shown in the previous page.
To fill the system, attach a water source to valve inlet 2 ensuring that the thermostatic blender is wound down to low. The water will the fill the loops of pipe and return out through valve 4, this should have a length of hose emptying into a bucket or drain. Valves 2 & 4 should be in the open position. Note if using 2 loops an effort should be made to keep the loops as close to the same length as possible.
Electrical


• All wiring should be undertaken by qualified personnel in compliance with international and local regulations.
• A fused spur should be provided adjacent to Single circuit mixing unit to provide power.
• The connection box is supplied with a link instead of the room thermostat. In case a room thermostat is required, remove the link (A in diagram above) and connect the thermostat in its place.
• The pump comes pre-wired to the connection box.